<LOGO>
FM Transmitter Measurement Report
Created: 2025-05-22 19-03-47
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 63 dBuV ISKELMA
Pilot RDS Phase Difference
6.4 kHz 2.7 kHz -84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 65 kHz 19002 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,0 dBr 5,20 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 65 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2025/05/22 19.02.43 Total samples: 19002 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000 4000
FM Scope MAX: 6,4 dBr MIN: 3,0 dBr AVE: 5,20 dBr % above 12,2 dBr: 0,0 Last value: 3,9 dBr (2025/05/22 19.02.42) 18.48 18.50 18.52 18.54 18.56 18.58 19.00 19.02 0 2 4 6 Pm [dBr]